Answers to the questions we get asked on the phone several times a month.

7 min read

How to size a UPS for an industrial load

Most undersized UPS installations we are called out to went wrong at the quotation stage, not on site. Almost always for the same three reasons.

Read it

6 min read

Servo stabilizer or UPS?

These two get compared constantly and they are not alternatives. One fixes voltage, the other fixes continuity. Knowing which problem you have takes a week and a logger.

Read it

6 min read

Why UPS batteries fail early in Pune

A VRLA battery rated for five years will often manage two and a half here. The cause is almost never the battery — it is the room it sits in.

Read it

8 min read

What to check before signing a UPS AMC

Two contracts on the same machine can differ by three times in price and by rather more than that in what you actually receive. The difference is almost never on the front page.

Read it

8 min read

Reading a UPS spec sheet without being fooled

Almost nothing on a UPS datasheet is untrue. Quite a lot of it is true under conditions the sheet does not print.

Read it

9 min read

Lithium vs VRLA for UPS banks in India

The interesting variable in India is not price. It is the temperature of the room the bank is going to live in.

Read it

8 min read

Online UPS vs offline UPS

One rebuilds the waveform continuously; the other passes the mains through and switches to battery when it fails. That single difference decides which one your equipment needs — and for a lot of loads, the cheaper answer is the correct one.

Read it

9 min read

How to compare UPS manufacturers

Most of the firms listed as UPS manufacturers in Pune assemble imported cabinets or resell somebody else’s. That is a legitimate business, but it is a different one, and it changes who answers the phone in year seven.

Read it

7 min read

What rooftop solar does to your UPS

Plants that put solar on the roof often find the UPS behaving differently within weeks. Nothing has failed — the supply it is watching has changed character, and the UPS is doing exactly what it was told to.

Read it

8 min read

Why a DG set and a UPS argue

The generator starts, the changeover closes, and the UPS stays on battery as though nothing happened. This is the most common complaint on sites running both, and it is almost never a fault in either machine.

Read it

7 min read

What a UPS costs to run

A double-conversion UPS is one of the few things in a plant that runs at full duty every hour it is switched on. Four points of efficiency, on a 100 kVA load, is roughly a lakh a year — which is frequently more than the price difference that bought it.

Read it

7 min read

What EV chargers do to an industrial supply

A fleet charger is not another motor. It is a large, non-linear load that can go from nothing to full draw in seconds, several times a shift, on a connection sized before anyone owned an electric vehicle.

Read it

7 min read

Your server room got denser

One machine can undo the sizing of a whole room. A rack that drew four kilowatts for a decade is being replaced by one drawing thirty, and the UPS in the corner was specified against the old number.

Read it

8 min read

How to read a power quality report

A logger produces a hundred pages and a recommendation on the last one. Four measurements decide what you actually need, and knowing which they are turns the report from a sales document into a specification.

Read it