10 kVA online UPS
10 kVA
The crossover point in the range. Eight kilowatts of real output, and the only rating we build with either input configuration — single phase on a 192 V bank, or three phase on a 240 V bank. Output is single phase in both cases.
- 10 kVA
- Rated capacity
- 8.0 kW
- Real output at 0.8 pf
- 192 V (1Ph input) or 240 V (3Ph input)
- Battery bus
- 1 phase
- Input supply
10 kVA Online UPS — rating card
| Series | EPS-1PH-SERIES |
|---|---|
| Rated capacity | 10 kVA |
| Rated output power | 8.0 kW |
| Input configuration | Single phase + neutral, 220 / 230 / 240 VAC |
| Input voltage range | 170 V – 280 V |
| Output configuration | Single phase + neutral + ground |
| Rated output voltage | 220 / 230 / 240 VAC ±1% |
| Battery voltage | 192 V (1Ph input) or 240 V (3Ph input) |
| Topology | True double conversion online |
| Transfer time | 0 ms (true online) |
| Efficiency | Up to 96% |
| Output waveform | Pure sine wave |
| THDv (linear load) | < 3% |
| THDv (non-linear load) | < 5% |
| Output power factor | 0.8 lag |
| Voltage regulation | ±1% |
| Overload capacity | 110–150%: 30 s · > 150%: 2 ms |
| Input frequency | 48 – 52 Hz |
| Input power factor | > 0.90 (PFC) |
| Output frequency | 50 Hz |
| Battery type | External tubular and SMF |
| Charge current | Adjustable 1 A – 12 A |
| Recharge time | < 8 hrs to 90% capacity |
| Battery protection | Over-voltage / under-voltage |
| Operating temperature | 0 °C – 40 °C |
| Humidity | 5% – 95%, non-condensing |
| Communication | RS-232 |
| Protection class | IP20 |
| Cooling | Forced air, variable speed fans |
| Mobility | Heavy-duty caster wheels |
Typical values for the standard build. Configured to order — your general arrangement drawing carries the figures that apply.
10 kVA Online UPS — questions
Anything not covered here, call us — most of it is faster to answer on the phone.
Should I take the single-phase or three-phase input version of the 10 kVA?
If you have a three-phase connection, take the three-phase input. Eight kilowatts drawn from one phase is a heavy single-phase load and it unbalances the incoming supply; spread across three phases it is unremarkable. Output is single phase on the EPS-3PH1PH-SERIES and three phase on the EPS-3PH3PH-SERIES, both available at this rating.
Does the 10 kVA give a three-phase output?
It depends on the series. The EPS-3PH3PH-SERIES outputs three phase plus neutral plus ground from 10 kVA up. The EPS-1PH and EPS-3PH1PH series output single phase plus neutral plus ground — on the latter, the three-phase reference is to the input side only. At 10 kVA both are available, so say which the load needs and we will quote the right one.
Other capacities
3 kVA Online UPS
5 kVA5 kVA Online UPS
6 kVA6 kVA Online UPS
7.5 kVA7.5 kVA Online UPS
15 kVA15 kVA Online UPS
20 kVA20 kVA Online UPS
30 kVA30 kVA Online UPS
40 kVA40 kVA Online UPS
50 kVA50 kVA Online UPS
60 kVA60 kVA Online UPS
80 kVA80 kVA Online UPS
100 kVA100 kVA Online UPS
120 kVA120 kVA Online UPS
150 kVA150 kVA Online UPS
180 kVA180 kVA Online UPS
200 kVA200 kVA Online UPS
Where we supply and attend
10 kVA Online UPS units are built at our Pune works and delivered, installed and commissioned across the city and the industrial belt around it.
Outside these areas we contract individually against distance, and we will tell you honestly if the response time you need is not one we can hold to. All areas served
Not sure this is the right size?
Send the load list. Sizing against inrush rather than running load is where most undersized installations go wrong, and it costs nothing to check.